You cannot select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
docs/docs/smart-home/wirenboard/new-controller.md

35 lines
1.6 KiB
Markdown

This file contains ambiguous Unicode characters!

This file contains ambiguous Unicode characters that may be confused with others in your current locale. If your use case is intentional and legitimate, you can safely ignore this warning. Use the Escape button to highlight these characters.

новый контроллер
https://wirenboard.com/wiki/Wiren_Board_7.4
обновляем прошивку https://wirenboard.com/wiki/Wiren_Board_7.4_Firmware_Update#web-ui
сменить пароль рута https://wirenboard.com/wiki/SSH#%D0%9B%D0%BE%D0%B3%D0%B8%D0%BD_%D0%B8_%D0%BF%D0%B0%D1%80%D0%BE%D0%BB%D1%8C
защитить веб интерфейс https://wirenboard.com/wiki/%D0%97%D0%B0%D1%89%D0%B8%D1%82%D0%B0_%D0%BF%D0%B0%D1%80%D0%BE%D0%BB%D0%B5%D0%BC
Установите верный часовой пояс. https://wirenboard.com/wiki/Time
```
timedatectl set-timezone Asia/Yekaterinburg
```
## Новое устройство для Modbus
Первым делом, увеличиваем скорость работы. Со стандартных 9600 на 115200, что соответствует "быстрому modbus"
Подключаемся к контроллеру по ssh и останавливаем службу `wb-mqtt-serial`. Затем выставляем нужную скорость и запускаем службу обратно.
```bash
systemctl stop wb-mqtt-serial
modbus_client --debug -mrtu -b9600 -pnone -s2 /dev/ttyRS485-2 -a212 -t0x06 -r110 1152
systemctl start wb-mqtt-serial
```
Разберем 2 строчку подробнее:
- `-b9600` - текущая скорость работы
- `-a212` - адрес устройство в modbus
- `/dev/ttyRS485-2` - через какой интерфейс подключаемся
- `-r110 1152` - записываем в регистр **110** значение скорости *115200*